for doors with fire resistance and smoke control requirements

  • Backplate interior module

  • Reader module as escutcheon with PC aperture (access control)

  • Reader module as escutcheon with PC aperture (access control)

  • Door sign interior module with CMC

  • Define lever handle and opening direction

    see key

    The inwards or outwards opening direction must be selected for the mortice lock.

    ① Interior module
    ② Exterior module
    (access control)
    ③ Exterior module, outwards opening, DIN left mortice lock

  • Define lever handle and opening direction

    see key

    The inwards or outwards opening direction must be selected for the mortice lock.

    ① Interior module
    ② Exterior module
    (access control)
    ④ Exterior module, inwards opening, DIN right mortice lock

  • Define lever handle and opening direction

    see key

    The inwards or outwards opening direction must be selected for the mortice lock.

    ① Interior module
    ② Exterior module
    (access control)
    ⑤ Exterior module, inwards opening, DIN left mortice lock

  • Define lever handle and opening direction

    see key

    The inwards or outwards opening direction must be selected for the mortice lock.

    ① Interior module
    ② Exterior module
    (access control)
    ⑥ Exterior module, outwards opening, DIN right mortice lock

91766160 product photo

Door terminal modules, Häfele Dialock DT 400c FH, with thumbturn

for doors with fire resistance and smoke control requirements, for interior guest room doors, matt

Art. no. 917.66.160
91766161 product photo

Door terminal modules, Häfele Dialock DT 400c FH, with thumbturn

for doors with fire resistance and smoke control requirements, for exterior guest room doors (outdoor version), matt

Art. no. 917.66.161
Product details
  • RFID technologies: ISO15693, ISO14443, Tag-it ISO, MIFARE Classic EV1, MIFARE DESFire EV1/EV2/EV3
    Low Power Wireless technologies: Bluetooth Low Energy
    Memory: For up to 1,000 audit trail entries, for up to 1,000 user keys
    Ambient temperature of operation (Outdoor version): Exterior module -20°C – +60°C (*), interior module 0°C – +55°C
    Tested to: DIN 18273

Product type

Door terminal module

Distance

72,00 mm

Colour/finish

Matt

Area of application

for fire resistant and smoke control doors, for interior guest room doors or as outdoor version for exterior doors

Transponder technology

Tag-it™-ISO®, MIFARE® DESFire® EV2, RFID, MIFARE Classic® EV1, MIFARE® DESFire® EV1

Functionality

battery-operated, intelligent door terminal, contactless activation using Dialock key
- Indication of unlocking and locking with white/red LEDs
- Door backplate interior module with rotary knob with which "Do not disturb" can be indicated on the reader module with a flashing signal
- Door backplate interior module with battery compartment
- The door can be opened from the inside without a key at any time
- electronic and mechanical emergency opening is possible
- for service personnel: Indication of programming status and when battery change is required
- with real-time clock and logging of all procedures, including electronic and mechanical emergency openings
- RFID interface for programming
- Bluetooth interface for My Dialock Manager app

Options

Escutcheon foil for reader module with PZ or as blind cover

Installation note

Please note the following dimensions during installation as a functional unit:
- A external length, relevant for profile cylinder selection
- B internal length, relevant for profile cylinder selection, must not be longer than dimension B1
- C external door thickness, relevant for selection of spindle, spacer plate
- D internal door thickness, relevant for spindle selection
- E total door thickness, relevant for mounting screw selection

Material

Backplate interior module: Stainless steel
Reader module: Plastic

Order reference

The following must also be ordered for a fully operational unit:
Ⓑ 1 mortice lock for DT 400c
Ⓒ 2 lever handle aperture parts
Ⓓ 1 single cylinder for mechanical emergency opening
Ⓔ 1 escutcheon foil
Ⓔ 1 spindle
Ⓕ 1 set of mounting screws for reader module and interior module
Ⓕ 4 batteries

Supplied with

1 reader module as reader unit with escutcheon
1 interior module with CMC

Technical data attributes
Technical data
Degree of protectionIP40IP54
Ambient temperature0 – 55 °C
Relative humidity10 – 95 %10 – 95 %
Type of voltage supplyBatteryBattery
Type of batteryAA Mignon 1.5 VAA Mignon 1.5 V
Spindle9 mm9 mm
Door thickness33 – 108 mm33 – 108 mm
Suitability according to EN 179YesYes
Additional information attributes

Notes on operation and installation

Planning by Dialock specialist is required.
DT 400c FH door terminal modules must be installed by Dialock specialists after approval by the door manufacturer. Otherwise the Fire and Smoke Control Certificate for the door will be invalidated.

Only to be used in combination with DIN mortice lock for DT 400c. The comfort function is set via the mortice lock.

Mechanical emergency opening
If the product is installed without a mechanical emergency opening facility, it may not be possible to open the door from the outside in the event of fault. If emergencies occur inside the room during the fault, rescue work will be hindered.
The operator must ensure that doors on which this product is installed have a mechanical emergency opening facility using a profile half cylinder in the event of fault. Only mortice locks with key action function are permitted for this purpose. Observe the installation conditions of the respective version (e.g. FH).
Häfele is not liable for damage that is attributable to failure to install a mechanical emergency opening facility.
When using the mechanical emergency opening, please note the information sheet for determining the length of the single profile cylinder (operating instructions can be found in our online shop "www.hafele.com").

Outdoor version
Only the reader module is suitable for outdoor use. Please note the installation specifications for this version.
*Please note: -20 °C only in the case of a weather-protected installation, otherwise there is a risk of the coupling freezing. The ambient temperature is reduced to 0°C - +60°C when exposed to weathering.
The outdoor version must be approved by Häfele for the respective installation site. Extreme locations such as salty environments are not possible.
Please contact your appropriate Häfele member of staff when ordering the product.

Battery change:
We recommend changing the batteries before the winter months with the outdoor version.

Complementary products and accessories
Häfele SE & Co KG, Adolf-Häfele-Str. 1, 72202 Nagold, Deutschland
Tel: +49 (0) 74 52 / 95 - 0, Fax: +49 (0) 74 52 / 95 - 2 00, E-Mail: info@hafele.com.de
24.05.2025